Yiwu Plating Factory 100A/300A/500A-12V Rectifier

  • Description
Product Detail

     

     

    100A/300A/500A-12V  Rectifier 

     

    Model No

    MX (100)A- -(12) V

    Power

    1.2KW

    Circuit Mode

    IGBT/PWM

    Control Interface

    Front Panel

    AC Input

    Phase

    Single Phase

    Input Voltage

    AC220V±15%

    Frequency

    60HZ±3HZ

    DC Output

    Output Current

    0-100AContinuously adjustable

    Output voltage

    0-12V Continuously adjustable

     

    Output precision

    Precision of CC =1%, Precision of CV: =1% (entire average),

    Ripple factor

    ripple =5%

    Display and regulation

    VOLT, AMPE, 0-Rated Value (Stepless adjustable)

    Working pattern

    CC/CV

    Output Status

    Constant current: Voltage change according to load changed, Constant voltage: Current change according to load changed

    Cooling way

    Forced air cooling

    Operation environment

    Site

    Indoor

    Environment Temperature

    -20°C~45°C

    Relative Humidity

    5?~95%

    Altitude

    ?1500M

    Protection

    input over and under voltage, input phase loss, output overvoltage, output over current, output short circuit, water pressure, overheat and driving protection

     

    Model No

    DR(500)A- -(12) V

    Power

    6KW

    Circuit Mode

    IGBT/PWM

    Control Interface

    remote box

    AC Input

    Phase

    Single Phase

    Input Voltage

    AC220V±15%

    Frequency

    60HZ±3HZ

    DC Output

    Output Current

    0-500AContinuously adjustable

    Output voltage

    0-12V Continuously adjustable

     

    Output precision

    Precision of CC =1%, Precision of CV: =1% (entire average),

    Ripple factor

    ripple =5%

    Display and regulation

    VOLT, AMPE, 0-Rated Value (Stepless adjustable)

    Working pattern

    CC/CV

    Output Status

    Constant current: Voltage change according to load changed, Constant voltage: Current change according to load changed

    Cooling way

    Forced air cooling

    Operation environment

    Site

    Indoor

    Environment Temperature

    -20°C~45°C

    Relative Humidity

    5?~95%

    Altitude

    ?1500M

    Protection

    input over and under voltage, input phase loss, output overvoltage, output over current, output short circuit, water pressure, overheat and driving protection

     

     

    Model No

    MX (300)A- -(12) V

    Power

    3.6KW

    Circuit Mode

    IGBT/PWM

    Control Interface

    remote box

    AC Input

    Phase

    Single Phase

    Input Voltage

    AC220V±15%

    Frequency

    60HZ±3HZ

    DC Output

    Output Current

    0-300AContinuously adjustable

    Output voltage

    0-12V Continuously adjustable

     

    Output precision

    Precision of CC =1%, Precision of CV: =1% (entire average),

    Ripple factor

    ripple =5%

    Display and regulation

    VOLT, AMPE, 0-Rated Value (Stepless adjustable)

    Working pattern

    CC/CV

    Output Status

    Constant current: Voltage change according to load changed, Constant voltage: Current change according to load changed

    Cooling way

    Forced air cooling

    Operation environment

    Site

    Indoor

    Environment Temperature

    -20°C~45°C

    Relative Humidity

    5?~95%

    Altitude

    ?1500M

    Protection

    input over and under voltage, input phase loss, output overvoltage, output over current, output short circuit, water pressure, overheat and driving protection